Tuesday, September 30, 2014

Running Firebird database server as application

0. Download firebird from: http://sourceforge.net/projects/firebird/files/
1. Unzip  Firebird-xxxxxxx-xxxxx.zip
2. Go to bin folder.
3. Execute fbserver with "-a" switch.
--------------------------------------------------
Example for windows:

Start cmd.exe and type:
cd Path_to_firebird\bin [enter]
fbserver.exe -a [enter]

(Use Flamerobin's "Register existing database..." option to connect to a .fdb file,
and then edit and view the contest of the same.
For username | password combo try: sysdba | masterkey)

Friday, September 26, 2014

Maxima Tutorials

Some tutorials about using Maxima , computer algebra system :
http://setrst.byethost10.com/_blog/maxima/

Maxima links and resources: http://mathscitech.org/articles/maxima

Sunday, September 14, 2014

Thursday, November 28, 2013

Trainer for Windows 3D pinball - Space Cadet

(tags: cheat, trainer, windows, 3d pinball space cadet)

Download Space cadet trainer.

1) Unzip and copy "3d.PINBALL.Space.Cadet.trained.exe" in the same folder as pinball.exe.
Pinball.exe should be somewhere in Program Files (\Windows NT\
Pinball (on Win XP)).

2) Launch "3d.PINBALL.Space.Cadet.trained.exe".

3) Go to Game and check "Always Re-Deploy".

(Cheat works by making Re-Deploy always ON.)

4) Have fun ;)


Wednesday, June 19, 2013

FREE SMS/TXT SITES

1) http://afreesms.com/freesms/ (Let's you spoof the "Sender ID" field.)
2) http://globfone.com/ (Sends flash type of message,which just shows up on your display,no interaction is needed.)
3) http://www.talksms.com/ (1 free sms per day)
4) http://pc2mobile.net
5) http://www.socialland.net/sendsms.php (user: nicksloter, pass:?)
6) http://freesmscell.net/sms.php
7) http://www.dailysms.us

8) http://www.dosms.me/sms.php

9) http://www.freesms.net
----------------------------
10) http://www.armsms.com

Tuesday, February 26, 2013

Poynting and Heaviside energy flow

Taken from: John D. Kraus, Electromagnetics, Fourth Edn., McGraw-Hill, New York, 1992

Inside (supeconducting) wires is E=0, because sigma->inf. J=sigma*E. "The electric field inside an ideal conductor will be zero when under static conditions. In this case, a current can flow without an electric field present inside the conductor. But this is only true for an ideal conductor, like a superconductor. "

...

In a non-ideal conductor, such as a real world wire or metal plate, a small electric field is required to maintain a constant flow of current under constant potential. This is only true because the electric field, which is directly related to the electric force on the charges in the wire, must overcome the non-zero resistance of the wire."

Link here:https://physics.stackexchange.com/questions/388541/current-in-a-conductor/388888#388888

Wednesday, August 29, 2012

BETAMAX VoIP Calling rates



On the link below you can find calling rates comparison chart for Betamax VoIP companies:

http://backsla.sh/betamax

Friday, June 8, 2012

Various physics and math formulas

Electric engineering, (plasma) physics and math formulas:

LINK:

https://sites.google.com/site/little0nemoblog/home/formulas

Sunday, January 1, 2012

How to Clean / Remove / Disinfect any known virus(es)



Cleaning / Removing / Disinfecting any known virus(es).

Here's how to eradicate Win32.Sality or any other known
virus(es):


Solution 1 (This is only for Win32.Sality) :
Download salitykiller from http://support.kaspersky.com/viruses/utility run it, wait, and that's all. The end;

Solution 2 (This is for all known viruses) :
Using Kaspersky Rescue Disk. It can be made to boot from USB (many people want/like this approach) or to boot from CD/DVD. Links:

-For USB flash boot option: 
http://support.kaspersky.com/viruses/rescuedisk/main?qid=208282163

-For DVD/CD boot option (you need burning software, CDBurnerXP is free):
http://support.kaspersky.com/viruses/rescuedisk/main?qid=208282484

Kaspersky Rescue Disk is HERE.

Sunday, August 14, 2011

NDIS User-mode I/O Driver clogging XP

Ndisuio.sys is not spyware or any other malware.
It gains access to NDIS devices and processes through
IOCTL_NDISUIO_OPEN_DEVICE, and receives only those frames
that have an NDIS_MEDIUM type of NdisMedium802_3.
(source: http://msdn.microsoft.com/en-us/library/ms901264)
Sysgate firewall's traffic log clearly shows zero for outgoing traffic and non zero for incoming. It will just locally duplicate traffic.

ndisuio.sys outbound traffic is zero, 0 kb. Ndis.sys traffic issue



 If you don't use wireless networking just disable
"Wireless Zero Configuration" service.

If you do use Wi-Fi connection then this service is set to
'manual' or 'automatic', and it is (probably) running. So, after you connect to a wireless network, just stop this service and ndisuio.sys will stop with this behavior. No more data coming in for it anymore !
(note: to connect again to a wi-fi network, WZC needs to be started again.)

To deal with WZC service (or any other), do this:
Click "start", then click "run" and type "services.msc". Scroll all the way down to the bottom. Right click it and choose "Start" or "Stop", for starting and stopping it ;)
To change it's start up option, choose "properties" (or use double left click instead of right click).
Under "Startup type:" pick what you need. Click "OK" and that's it.